TR4 Direct

TR4 Direct

Category: Safety switches

Specifications
Actuator coding level
Low coding level, High coding level
Boundary area indication
No, Yes
Certificate
EC-Type-Examination approval, China-RoHS, EU declaration of conformity, UK declaration of conformity, ACMA declaration of conformity, cULus certificate
Challenge
No wear, manipulation protection, Door offset, Heavy contamination, Simple diagnostics
Coding
universally coded, uniquely coded
Connection type
cable, cable with plug M12, 8-pin, cable with plug M12, 5-pin
Design
cylindrical, rectangular
Emergency stop pushbutton (illuminable)
No
Enclosure rating
IP69K, IP67
Escape release
No
Functional principle
RFID
Housing diameter
M18
Housing material
plastic
LED
Yes
Length of cable
3 m, 10 m, 0.2 m
Magnetic retaining force
Yes, No
Plus/minus button
No
Product family
TR4 Direct
Product segment
Safety switches
Product subsegment
Non-contact safety switches
Product type
RFID safety switch
Protective collar
No
Pushbuttons
No
Retaining force
10 N
Safe series connections
with Flexi Loop (with diagnostics), with T-connector (without diagnostics), in control cabinet (with diagnostics)
Safety level
PL e, SIL 3
Safety task
Safe monitoring of doors and flaps
Sensing range
25 mm, 15 mm
Suitable for muting applications (with UE403)
No
Suitable for reset/override applications (with deTec4)
No
System part
Sensor with actuator
Type of output
Self-monitoring semiconductor outputs (OSSDs)
Details

RFID safety switch for door monitoring with manipulation protection
The TR4 Direct RFID safety switch is used for applications where a high level of manipulation protection is required.
TR4 Direct has monitored semiconductor outputs (OSSD) and can therefore be connected directly to a safety controller. The safety switch is only released if a valid actuator is located within the response range of the TR4 Direct. Two actuation principles are available: For universally coded variants, any universally coded actuator can be located in the response range. For uniquely coded variants, only the uniquely coded actuator that has been taught in with the matching code stored may be located within the response range. Up to 30 safety switches, all with LED status indicators, can be connected in series, thereby making electrical installation and service both straightforward and convenient.

TR4 Direct AT A GLANCE
Benefits

-High level of manipulation protection due to individually coded actuator (depending on the type)
-High level of machine availability due to large door offset tolerances and periphery indicator
-High level of reliability due to resistance to shock and vibration
-Economical solution due to series connection of up to 30 sensors
-Long product service life due to low-wastage and low-maintenance configuration
-Fast diagnosis via LED status indicator
-The devices are easy to clean, making them ideal for use in highly contaminated areas or applications with stringent hygienic requirements
-Flexi Loop: Reliable series connection including diagnostics with minimal wiring work

Features
-Response range of up to 25 mm
-Unique and universally-coded sensors up to enclosure rating IP 69K
-Up to performance level PL e (EN ISO 13849)
-Two OSSD safety outputs
-Reliable series connection of up to 30 sensors possible (depending on the variant)
-LED status indicator
-Periphery indicator and magnetic holding force (optional)
-Flexi-Loop-compatible M12 plug connector (depending on the variant)


View more about TR4 Direct on main site