Ambient operating temperature
-40 °C ... 55 °C
Applications
normal industrial environment
Certificate
MAR declaration of conformity, cTUVus certificate, EC-Type-Examination approval, ACMA declaration of conformity, EU declaration of conformity, UK declaration of conformity, China-RoHS
Connection type
male connector M12, 4-pin
Design
cylindrical
Diagnosis
Visual display on device
Diameter
M18, M30
Direction of cable connection
straight, angled
Enclosure rating
IP67
End cap with integrated LED
No
Functional principle
Sender/receiver
Functions
protective operation
Housing material
Plastic PBT, nickel-plated brass
Lens material
glass
Light source
LED
Number of beams
1
Optical axis
radial, axial
Product family
L21
Product segment
Safety light-beam sensors
Safety level
PL c, SIL 1, Type 2
Safety task
Multi-sided access protection, Monitoring of doors and flaps, Lateral protection of AGVs, Collision protection at barriers and gates, Single-sided access protection
Scanning range
7 m, 16 m, 84 m
System part
receiver, pair, sender
Type of light
visible red light
Wave length
660 nm
Details

Cylindrical design for safety applications up to type 2
The L21 single-beam photoelectric safety switch consists of a sender and receiver. The test input on the sender allows direct functional tests. Performance level PL c in acc. with EN ISO 13849-1 or Type 2 in acc. with IEC 61496 can be achieved in conjunction with a safety controller. Suitable safety controllers are, for example, Flexi Classic or Flexi Soft. Color LEDs provide local information about the operational status. The required range can be selected from various device versions. All versions are suitable for outdoor applications and enable even complex safeguarding tasks to be accomplished by using deflector mirrors.

L21 AT A GLANCE
Benefits

-Easy integration due to small, compact versions with maximum range
-Directly connect to a safety controller – reducing costs
-Flexible device integration makes it possible to set up individual access protections
-Well suited to withstand extreme ambient conditions such as heat, cold or moisture

Features
-Type 2 (IEC 61496), SIL1 (IEC 61508), PL c (EN ISO 13849), only in conjunction suitable testing device, e.g., Flexi Classic or Flexi Soft
-Small M18 sensors with ranges up to 10 m
-Compact M30 sensors with ranges up to 60 m
-Enclosure rating IP 67
-Temperature range from –40 °C ... 55 °C
-Metal and plastic version
-Radial optics (90° deflector mirror)
-Straightforward diagnostics and service