Speed Monitor

Speed Monitor


Specifications
Applications
Stand-alone
Certificate
China-RoHS, UK-Type-Examination approval, ACMA declaration of conformity, EC-Type-Examination approval, cULus certificate, cTUVus certificate, UK declaration of conformity, EU declaration of conformity
Configuration method
via rotary switch
Connection type
screw-type terminals, spring terminals
Drive safety functions
standstill, safely-limited speed (SLS), safe speed monitoring (SSM)
Encoder interface
A/B incremental encoder, HTL 12 V or 24 V, Proxy
Product family
Speed Monitor
Product segment
safe motion monitoring and control
Safety level
PL e, SIL 3
Selectable speed limit
0.5 Hz ... 99 Hz, 0.1 Hz ... 9.9 Hz
Supply voltage
24 V
Task
Protecting people - Safe monitoring of machine movements
Details

Optimal safety protection in maintenance mode
The Speed Monitor is a zero-speed drive monitor that protects against dangerous movements by safely monitoring speed. It has different safety drive functions, such as SLS (safety limited speed) and SSM (safe speed monitor). In addition, the MOC3SA offers different operating modes: one mode with two independent proximity sensors, or a mixed mode with oneproximity and one signal output. The Speed Monitor is connectable to all SICK safety controllers.

Speed Monitor AT A GLANCE
Benefits

-Easy commissioning – using only a screwdriver – reduces installation time
-Tool backup using the Flexi Soft Designer and the Flexi Classic Configurator
-Additional HTL encoder evaluation
-Cascading of units is possible

Features
-Zero-speed and drive monitoring
-4 safe semiconductor outputs
-PL e (EN ISO 13849), SIL3 (IEC 61508), SILCL3 (EN 62061)
-Maximum input frequency of 2 kHz
-Adjustable monitoring limit/monitoring frequency from 0.1 to 9.9 Hz or 0.5 to 99 Hz
-2 application diagnostic outputs for failure and status display
-Diagnostic LEDs

 


View more about Speed Monitor on main site